Forum Post: RE: tmp006 calculation

$
0
0

Hi Luo,

There is no "work around" since the part is working properly. The only way to guarantee that the TOBJ will equal TDIE is to place an object with high emissivity (good radiator of IR energy) in front of the TMP006 that is also at room temperature. Otherwise, TOBJ will be a function of the wall or ceiling temperature (or whatever is in the device's field of view). If these surfaces are not made of high-emissivity material, then they will only output a small amount of IR energy and therefore TOBJ will be less than TDIE.

Best regards,

Ian Williams