Forum Post: RE: TMP300 active

Hello Max,If you set the temperature resistor Rtemp to a particular value, OUT will toggle only when temperature exceeds the set temperature setting. 0deg C in your case.OUT signal is open drain output...

View Article


Forum Post: RE: LM71 interface question

Hi Peter,Thank you for your inquiry. Should you provide 16 clocks or 32 clocks? It depends on what you want to do. Normally, reading the temperature data is only required 16 clocks, but when you want...

View Article


Forum Post: RE: Constant current source LM234

Thanks for your reply. 

View Article

Forum Post: RE: Need information- LM92CIMX/NOPB

Hi Jayakumara,Sorry for the delay. The attached file is the information that you’re requested. Please let me know if you have further question.(Please visit the site to view this file)Aaron

View Article

Forum Post: 2 channel sine wave generation at 35 to 40V output voltage

Hi,Can you please help me in selecting an IC for 2 channel sine wave generation at 35 to 40V for frequency ranging from 20KHz to 40KHz. i have tried TI's range but couldn't locate suitable. if one IC...

View Article


Forum Post: RE: TMP006 first sample after power up

Hello,Thank you for your contributions which confirm our problem! The current solution is as follows: power up, waiting for four samples (microcontroller in sleep mode), read out the values ​​and power...

View Article

Forum Post: RE: Unable to run SensorEval Application

Hi Sam,I will send you the instruction shortly. Just to let you know that we are currently re-spinning the EVMs to work with Window XP or later. May I ask what device you are using with SensorEval...

View Article

Forum Post: RE: Selecting LED and photodiode

Deepak,TI has several partner companies that make LEDs and photodiodes and that list of companies is available at http://www.ti.com/lsds/ti/analog/webench/partner-leds.page.  I would try inquiring at...

View Article


Forum Post: RE: TMP006: local heating causes cooler readings error

Hello Will,To answer your questions...1. Yes please use foam/ insulation materials behind the TMP006 PCB in order to reduce the effect of air through duct acting as a noise source. This will allow the...

View Article


Forum Post: RE: LM73 Power supply ramp-up issue

Hi Madhuri,Based on the temperature you provided, it seems that you had a slow ramp rate; therefore, the registers wasn't properly loaded into the eeprom. A power-on-reset (POR) will occur at a certain...

View Article

Image may be NSFW.
Clik here to view.

Forum Post: RE: TMP006 field of view

Greg,   The small metal cans are not commercially available.  I designed some and had FotoFab make me some. The prototypes are flat and I have to bend them.  See the pictures below.  www.fotofab.com...

View Article

Forum Post: RE: LMP91200 issues

Hi Tim,it is not mentioned, we have assumed that since a pH measurement can have as result both positive and negative voltages, a device with a single supply configuration (without any charge pump...

View Article

Forum Post: RE: LM98714 INCLK min range

 Hello   Hooman. Thank you  for  reply. The  min INCLK :5MHz  understood. and  thank you  It teaches  influence for 5MHz low-level.   Best  regard       Ben    from japn 

View Article


Forum Post: RE: TMP006 Question

Hello Eddy,To answer your questions:A1: You can increase the distance by restricting TMP006's Field of view by using lenses etc. I would like to confirm the distance requirements, is 1.5 meters? What...

View Article

Forum Post: RE: LM95234 / IBIS model

Aaron-san,Thank you for the answer.I submitted it to our customer.Best Regards,Kato / Japan disty

View Article


Forum Post: TSC2004 AUX and Temp conversions when display is touched

Can the TSC2004 be commanded to perform AUX input or Temperature conversions while the touch screen has pressure on the panel? The Table 6 on page 11 of SLAA359 seems to imply that while the pressure...

View Article

Forum Post: RE: AFE5809 LNA

Ran,No, the AFE5809 cannot operate in differential input mode. INM must be tied to ground through an external capacitor.Thanks,Chuck Smyth

View Article


Forum Post: RE: TMP006 Sensitivity Problem

Hello Gokhan,Yes, typically S0 would vary from 5 to 7E-14 but its completely depended upon a particular application. For industrial application like yours I wouldn't be surprised if your S0 is 2E-14....

View Article

Forum Post: RE: TMP006 plus lens

Hello Leonard,We haven't  tried measuring the PCB/Semiconductors with a lens setup. However, we have tried without using any lenses and were able to acheive ~1degreeC accuracy at a distance of 1cm from...

View Article

Forum Post: RE: TMP006 Question: About glass & human body

Hello Edward,Yes, I believe hair would influence the temperature results. Even though hair has high emissivity its temperature will be close to Ambient temperature unlike that of skin which regulates...