Forum Post: RE: LM96194 reset signal

$
0
0

Hi Prachi,

Yes, the reset signal will be held low for 250-330ms after it hits a certain threshold voltage during power up. The part will perform a reset at 2V even though the mininum threshold voltage is 1.6V.

-Michael Wong