Quantcast
Channel: Data converters
Browsing all 37527 articles
Browse latest View live

Forum Post: I have ADWA AD1230 ph sensor, it has coaxial BNC connector not...

Hi, With this sensor mostly I can not read Ph value. Some times I can read. But it effected from my hands. When I close my hands VOUT changes. I wonder that ADWA AD1230 ph sensor, it has coaxial BNC...

View Article


Forum Post: RE: CS input of TSC2046E

Hi, Andy-san, Thank you for your support. It was confirmed to the customer. When usually it is not suport, they say it is not to use otherwise. The purpose was to shorten the conversion time. Thanks,...

View Article


Forum Post: ADS1298R in Continuous mode Samples problem

Hi, Am using ADS1298R in Continuous mode. I configured it for 500 SPS in High resolution mode. I get the 27 bytes data through SPI and from them I have split the Lead1 and Lead2 data. But when i...

View Article

Forum Post: LM98620, how to get LVDS output with "more stable" & "low SNR"

Hi, all: I tried to set the LM98620 to get a " more stable " & " low SNR " output. However, it's difficult to both achieve this goal ("more stable" & "low SNR") in my settings. Maybe I put some...

View Article

Forum Post: DRV101 Different Packaging Replacement

Hi all, Any replacement recommended for DRV101T with different packaging more common nowadays? Thanks.

View Article


Forum Post: RE: DRV101 Different Packaging Replacement

Hi Hong, The DRV101T is in a TO-220 package, an alternative would be the DRV101FKTWT which is in a surface mount TO-263 package. I hope that helps!

View Article

Forum Post: A peak interference phenomenon using LM96551/LM96530/AFE5803

Hi, I'm using LM96551 / LM96530 / AFE5803 to build a prototype. 8 channels of the LM96551 were parallel connected to excite a 2000pF ultrasound transducer. A picture below shows a received signal. A...

View Article

Forum Post: RE: A peak interference phenomenon using LM96551/LM96530/AFE5803

Hello, I've got a question regarding the load that the LM96551 sees in your system. You mentioned 2,000pF ultrasound transducer while we anticipate from 200-300pF for the equivalent capacitive load!...

View Article


Forum Post: RE: A peak interference phenomenon using LM96551/LM96530/AFE5803

Hi, Hooman. Thanks for your reply. I'm sure we use a single element ultrasound transducer with a 2000pF capacitive load. That is why we use eight channels of the LM96551 parallel to increase the drive...

View Article


Forum Post: RE: A peak interference phenomenon using LM96551/LM96530/AFE5803

Hi, Here are some suggestions: 1. Add 2.5k resistor to ground on each LM96551 output pin, as shown below. The internal clamping diode(s) on each LM96551 output (see Block Diagram image in the...

View Article

Forum Post: RE: A peak interference phenomenon using LM96551/LM96530/AFE5803

Hi, Hooman Thank you very much for your reply. Yes, the LM96530 outputs are AC coupled to the AFE5803 . You give me really good suggestions from hardware view. I will change the values of the two...

View Article

Forum Post: ISO122 Isolator

I want to isolate a 0-10Volt analog signal but want the output voltage to be the same as the i input voltage. Is this the part to use? Thanks

View Article

Forum Post: RE: ISO122 Isolator

Hi Richard, Yes, the ISO122 can output your 0-10V signal.

View Article


Forum Post: LMP91200 Pin out

Hi Sir, I got the old LMP91200 datasheet, and it shows the pin 2, 3 is the CAL and RTD. The pin description defines these 2 pin to measure the Temp. and do the calibration. But we check the datasheet...

View Article

Forum Post: RE: A peak interference phenomenon using LM96551/LM96530/AFE5803

Hello, Unfortunately I'm not familiar with the operation of the AFE5803 and I cannot answer whether or not you need to do any high pass filtering in the software. Hopefully other people more familiar...

View Article


Forum Post: RE: A peak interference phenomenon using LM96551/LM96530/AFE5803

Phx, The AFE5803 has an AC coupled input and variable HPF in the LNA. The ADC also has a digital HPF. The analog HPF is recommended but let me know if you need to reduce the cut-off frequency. Thanks,...

View Article

Forum Post: Decrease sensitivity of capacitive touch screen FT5x06 Focal Tech.

Hi everyone, We're developing a custom board running Android 4.1.2 based on DM3730 processor with TI-Android-JB-4.1.2-DevKit-4.0.0 Releases. We chose the FT5x06 touch screen from Focal Tech. At...

View Article


Forum Post: RE: Decrease sensitivity of capacitive touch screen FT5x06 Focal...

Hi Nguyen, Sorry, I'm not able to help you with your questions since it it not a TI device. I would suggest you contact Focal Tech directly for some help. Andy

View Article

Forum Post: RE: Decrease sensitivity of capacitive touch screen FT5x06 Focal...

Thanks for your answer, Andy Liu ! However, can you tell me some ways to decrease the sensitivity of a capacitive touch screen in Android?

View Article

Forum Post: RE: A peak interference phenomenon using LM96551/LM96530/AFE5803

Hi,Chuck Smyth, Thank you for your kind help. The picture below is a 5MHz single excitation with the digital HPF function turned on. It seems work fine. However, when I use coded excitation. The low...

View Article
Browsing all 37527 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>