Forum Post: RE: Beamforming Problems

Hey Community,i have image problems with a beamforming board.to my person:age: 25work as elektonic-technicansome experience about audio hifi elektonic repair and development.my problem is that i want...

View Article


Forum Post: RE: TMP435 compatible Linux Device Driver

Thanks a lot Abhishek for your quick and clear answer.By the way, does TI maintain somewhere some sort of compliancy table for TMPxx device driver families?Best Regards,Patrick.

View Article


Forum Post: Noise in PCB

Hi,I designed a multi-layer mixed signal PCB. I separated analog and digital section planes(i.e. power supplies and grounds). Then I combined all the grounds at the power supply like as star topology....

View Article

Forum Post: RE: Beamforming Problems

Jakob,Is there a particular EVM or part number that you are working with?Meanwhile, here are some...

View Article

Forum Post: RE: TMP435 compatible Linux Device Driver

You are welcome Patrick.Regarding the compliance I'm afraid we do not. But feel free to ask us if you have any question on TMPXX device specifications.  Out of curiosity, whats your target application...

View Article


Forum Post: RE: Beamforming Problems

thank you for your answere:it its a medison accuvix V10 the P/N is bd-348-bf 0Athanks a lot ....

View Article

Forum Post: RE: REVERSE VOLTAGE PROTECTION ON INA3221

Terry,Are the voltages on the VIN+ and VIN- pins, referenced to GND, going below -0.3V?Per the data sheet, page 2, the difference between VIN+ and VIN- can be -26V to 26V, however, at no time can VIN+...

View Article

Forum Post: TSC2003 measuring up to 32VDC

I have a customer who would like to use the VBAT1 and VBAT2 on the TSC2003 to measure up to 32Vdc. Since there are built-in resistor voltage dividers on each input, could he simply just put a 47.5k ohm...

View Article


Forum Post: TSC2007 probe failed with AM3352 (SDK 07.00)

Guys,I posted a question on the Sitara forum, but I thought this might be a better place for the question. Has anyone had trouble with the TSC2007 linux driver with Kernel version 3.12?Here is my...

View Article


Forum Post: RE: TMP006 calibration with transient correction

Hi Lou,We have received your question. Please allow us some time to review  the two documents along with your questions and get back to you.Mayrim

View Article

Forum Post: RE: TMP431 Configuration register pointer address

Hello Timur,My apologies for the delay in getting back with you. We checked on the internal logic to confirm that Write operation to address 0x03 instead of 0x09 will deliver the same result.  While...

View Article

Image may be NSFW.
Clik here to view.

Forum Post: LMP91200 default Mode setup + problems

Hello sir,we have choosen LMP91200 for PH measurement..here is the sensor detailssensor has 3 pins and it is ISFET based sensor..The reference electrode(AG/Agcl) is inside a glass tube filled with KCL...

View Article

Forum Post: RE: TMP435 compatible Linux Device Driver

Hi, This is to do external thermal measurement capability for an existing HW.Thanks again.Patrick.

View Article


Forum Post: RE: LMP91200 default Mode setup + problems

hello,,any one help me out....strugling with short deadlines...what happen to Ti engineers////is no one who can help  me?

View Article

Forum Post: RE: Device for Body Temperature Measurement

Hi Nick,The answer depends on the use case; TMP006 and TMP007 are non-contact sensors (do not need to be in contact with the skin); the TMP112 requires good thermal contact to the skin.For non-contact...

View Article


Forum Post: RE: REF5050

[quote user="Marek Lis"]Even though REF5050 may work well beyond our specified 10-year life, we do not have the data to directly answer your question about the expected long-term shift after 20 years...

View Article

Forum Post: RE: TMP006 Fresnel lens

Hi Josh,Yes, best would be to have three holes in the housing, and use the polyethylene Fresnel lens over the TMP006/7. For the near IR sensor, the polyethylene may cause too much scatter - there are...

View Article


Forum Post: RE: TMP006 Drawing for sample covers?

Hi Bill,The TMP007 data sheet (SBOS685) , section 7.3.2 shows how to determine the field of view based on object size and distance.The upcoming TMP007 Layout and Assembly Guide will detail layout...

View Article

Forum Post: RE: LM34 Temp Sensor Max Wire Length

Hi,The maximum length is dependent on the stray capacitance of the wire and the environment that the wire is in. Watch out for noise coupling and follow the datasheet recommendations for capacitive...

View Article

Forum Post: RE: TMP006 calibration with transient correction

a1a2b0b1b2s0c20.00175-1.68E-053.184E-05-6.053E-06-4.796E-074.935E-1413Hi Luo, I have tried an initial calibration with the above co-efficients. THe data has rathre high nose and teh fit is not very...