Forum Post: RE: LMP91200 and EC probe
Hi Evgeniy,the Current at CAL pin can also be 200uA and 2mA. I didn't mention them just becasue I was refering to the order of magnitide of the current that the internal generator can source.The...
View ArticleForum Post: RE: TMP006 mystery
That is a very full and clear answer - its greatly appreciated.I'll do some more experiments over the next few days and get back to you.Kind regards!
View ArticleForum Post: RE: HDC1000 - how to isolate to get accurate readings
Hi Kayiita,Thanks for using TI E2E forum. I will forward this question to the HDC team. They will get back to you soon.Mayrim
View ArticleForum Post: RE: TMP122 Revision Differences
Hi Stefan,I did research all the changes applied to the TMP112AIDBVR and TMP122AIDBVRG4 for the last 4 years period. There is only one PCNs issued but it was cancelled. The proposed change was never...
View ArticleForum Post: RE: LM73 / abnormal temperature data
Hi Kensuke-san,Yes it is possible to read abnormal temperature data when there is power supply noise. The noise may be turning off the part when it falls below 2.7V.Make sure there are enough bypass...
View ArticleForum Post: RE: Analog and Digital Temperature Sensor with IEC 60730
Hi Mayrim-san,I believe some SVA products are compliant to the UL 60730 standards. For example, LM20B/C (analog temperature sensor), LM73C and LM75A/B/C (digital temperature sensor).It might be a good...
View ArticleForum Post: RE: The communication system for HDC1000EVM
Hi Atsushi,there is a way to retrieve the data from the EVM without using the GUI.Conenct the EVM to the PC.Open a telnet connection (such as using Termite) to the EVM (the EV M is recognized as a...
View ArticleForum Post: RE: HDC1000 - how to isolate to get accurate readings
Thank you! I will show them your post and that app note asap.
View ArticleForum Post: RE: functioning of LM 96570
Hi Anton,I've emailed you the software Maiusz had posted a while back:http://e2e.ti.com/support/other_analog/imaging_afes/f/239/p/243404/920804.aspx#920804Regards,Hooman
View ArticleForum Post: RE: LM96194 AD_IN6/7 voltage sensing error
Hi Emmy,Thanks for your suggestions. Will try it out and let you know.Regards,Sachin
View ArticleForum Post: RE: VSP8133 CCD AFE : noise issue?
Shimizu,As this device is Not Recommended for New Designs, all support is via e-mail. Please contact you local TI FAE for additional support.
View ArticleForum Post: RE: LMT86 data sheet, LMT85 data sheet, User's Guide for the...
Hi Murdock,You are absolutely correct. Please follow the pin diagram on the DCK package on the LMT85 and LMT86, ignore the pin functions table.The part numbers listed in the BOM are old and will be...
View ArticleForum Post: RE: Question of LM94022 certification
Hi Eddy,Emmy Denton will be answering your question offline.-Michael Wong
View ArticleForum Post: RE: LMP91200MT pH Sensor
Hi All,I need your suggestion, I am making pH meter by using LMP91200 IC. I did not able to find out ph by numeric calculation. I am finding by this waypH(X) = pH(S) + [ E(S) - E(X) / Z ] WherepH(S) =...
View ArticleForum Post: RE: TMP122 Revision Differences
Hi Stefan,I did not know that using another device was an option. In this case TMP112 can be a good replacement. The TMP112 device offers an accuracy of ±0.5°C without requiring calibration or external...
View ArticleForum Post: RE: TSC2006EVM-PDK USB Driver installation problem
There was an extra document on the CD that I missed. I needed to set one of SW-1, SW-2, or SW-3 to off. I set SW-2 off and the driver installs now.Thanks.
View ArticleForum Post: RE: Tmp102...Android support?
Hi Brady,We don't do Android support. However I have seen a few websites that have some sample codes developed by TI customers. You can used them as you starting point. I found one for Android 3.4....
View ArticleForum Post: RE: VSP8133 CCD AFE : noise issue?
Hi DHarmon Thank you for your reply. I unsestood.Best regardsShimizu
View ArticleForum Post: RE: Interfacing OPT101 with ADC
Hi, please visit www.ti.com and search for a new product, OPT3001. The output of OPT3001 is measured directly in lux.
View ArticleForum Post: RE: LMP91200MT pH Sensor
Hi Rahul,I suggest the follwing approach:Ph = 7 + Vout_LMP91200/alpha(T)Vout_LMP91200 is measured in mValpha(T) = -(1/298)*T*59.16 (mV/Ph init)T is measured in degKelvin When you read the output of...